Home  |   Archive  |   Online Submission  |   News & Events  |   Subscribe  |   APFA  |   Society  |   Contact Us  |   中文版
Search   
 
Journal

Ahead of print
Authors' Accepted
    Manuscripts
new!
Current Issue
Archive
Acknowledgments
Special Issues
Browse by Category

Manuscript Submission

Online Submission
Online Review
Instruction for Authors
Instruction for Reviewers
English Corner new!

About AJA

About AJA
Editorial Board
Contact Us
News

Resources & Services

Advertisement
Subscription
Email alert
Proceedings
Reprints

Download area

Copyright licence
EndNote style file
Manuscript word template
Guidance for AJA figures
    preparation (in English)

Guidance for AJA figures
    preparation (in Chinese)

Proof-reading for the
    authors

AJA Club (in English)
AJA Club (in Chinese)

 
Abstract

Volume 12, Issue 1 (January 2010) 12, 111–114; 10.1038/aja.2009.15

Improving precision in the assessment of round cell numbers in human semen

Trevor G. Cooper and Barbara Hellenkemper

Centre of Reproductive Medicine and Andrology, University of Münster, Domagkstrasse 11, D-48149 Münster, Germany

Correspondence: Dr Trevor G. Cooper, E-mail: TrevorG.Cooper@ukmuenster.de

Received 18 December 2008; Revised 7 January 2009; Accepted 3 February 2009

Abstract

The aim of this study was to increase the precision of assessment of the number of round cells observed in the peroxidase test for detection of seminal leukocytes (granulocytes). The dilution of semen was reduced and the volume of suspension examined was increased for semen samples containing between 0.6 and 6 million round cells per mL. A 1 + 5 (1:6) dilution was compatible with measurable peroxidase activity and a sufficiently clear background for cell assessment. At this dilution, and with assessment of all 18 grids on both sides of the Neubauer-improved counting chamber, only three of the 10 samples (nominal cell concentrations of 1.9 × 106 –3.3 × 106 mL−1) presented 400 round cells or more. As lower seminal dilutions were incompatible with easy detection of round cells or their peroxidase reaction product, it was not possible to provide precise measurements (sampling error 5%) of the suggested lower reference limit of 1 × 106 cells per mL. The results indicate that this poor precision of measuring 1 × 106 round cells per mL could explain the discrepant reports on the acceptability of the cut-off values for leukocytospermia. Such reference limits need to be established with statistically sound methods.

Keywords: cell number; peroxidase; precision; round cells; semen

PDF | PDF |

 
Browse:  4046
 
Asian Journal of Andrology CN 31-1795/R ISSN 1008-682X  Copyright © 2023  Shanghai Materia Medica, Chinese Academy of Sciences.  All rights reserved.