Asian Journal of Andrology (2010) 12: 111-114. doi: 10.1038/aja.2009.15

Improving precision in the assessment of round cell numbers in human semen

Trevor G. Cooper1 and Barbara Hellenkemper1

1 Centre of Reproductive Medicine and Andrology, University of Münster, Domagkstrasse 11, D-48149 Münster, Germany

Correspondence: Dr Trevor G. Cooper, Centre of Reproductive Medicine and Andrology, University of Münster, Domagkstrasse 11, D-48149 Münster, Germany. Fax: +49-251-835-6093 E-mail: TrevorG.Cooper@ukmuenster.de

Received 18 December 2008; Revised 7 January 2009; Accepted 3 February 2009.

Abstract
The aim of this study was to increase the precision of assessment of the number of round cells observed in the peroxidase test for detection of seminal leukocytes (granulocytes). The dilution of semen was reduced and the volume of suspension examined was increased for semen samples containing between 0.6 and 6 million round cells per mL. A 1 + 5 (1:6) dilution was compatible with measurable peroxidase activity and a sufficiently clear background for cell assessment. At this dilution, and with assessment of all 18 grids on both sides of the Neubauer-improved counting chamber, only three of the 10 samples (nominal cell concentrations of 1.9 × 106 –3.3 × 106 mL−1) presented 400 round cells or more. As lower seminal dilutions were incompatible with easy detection of round cells or their peroxidase reaction product, it was not possible to provide precise measurements (sampling error 5%) of the suggested lower reference limit of 1 × 106 cells per mL. The results indicate that this poor precision of measuring 1 × 106 round cells per mL could explain the discrepant reports on the acceptability of the cut-off values for leukocytospermia. Such reference limits need to be established with statistically sound methods.

Keywords: cell number, peroxidase, precision, round cells, semen

 