Home  |   Archive  |   Online Submission  |   News & Events  |   Subscribe  |   APFA  |   Society  |   Contact Us  |   中文版
Search   
 
Journal

Ahead of print
Authors' Accepted
    Manuscripts
new!
Current Issue
Archive
Acknowledgments
Special Issues
Browse by Category

Manuscript Submission

Online Submission
Online Review
Instruction for Authors
Instruction for Reviewers
English Corner new!

About AJA

About AJA
Editorial Board
Contact Us
News

Resources & Services

Advertisement
Subscription
Email alert
Proceedings
Reprints

Download area

Copyright licence
EndNote style file
Manuscript word template
Guidance for AJA figures
    preparation (in English)

Guidance for AJA figures
    preparation (in Chinese)

Proof-reading for the
    authors

AJA Club (in English)
AJA Club (in Chinese)

 
Abstract

Volume 22, Issue 2 (March 2020) 22, 154–157; 10.4103/aja.aja_5_20

Artificial urinary sphincter: current status and future directions

Culley C Carson

Department of Urology, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA

Correspondence: Dr. CC Carson (culley_carson@med.unc.edu)

25-Feb-2020

Abstract

Urge urinary incontinence (UUI) is one of the most troublesome complications of surgery of the prostate whether for malignancy or benign conditions. For many decades, there have been attempts to reduce the morbidity of this outcome with variable results. Since its development in the 1970s, the artificial urinary sphincter (AUS) has been the “gold standard” for treatment of the most severe cases of UUI. Other attempts including injectable bulking agents, previous sphincter designs, and slings have been developed, but largely abandoned because of poor long-term efficacy and significant complications. The AUS has had several sentinel redesigns since its first introduction to reduce erosion and infection and increase efficacy. None of these changes in the basic AUS design have occurred in the past three decades, and the AUS remains the same despite newer technology and materials that could improve its function and safety. Recently, newer compressive devices and slings to reposition the bladder neck for men with mild-to-moderate UUI have been developed with success in select patients. Similarly, the AUS has had applied antibiotic coating to all portions except the pressure-regulating balloon (PRB) to reduce infection risk. The basic AUS design, however, has not changed. With newer electronic technology, the concept of the electronic AUS or eAUS has been proposed and several possible iterations of this eAUS have been reported. While the eAUS is as yet not available, its development continues and a prototype device may be available soon. Possible design options are discussed in this review.

Keywords: artificial sphincter; bladder sling; prostate; sphincter; urinary incontinence

Full Text | PDF |

 
Browse:  1620
 
Asian Journal of Andrology CN 31-1795/R ISSN 1008-682X  Copyright © 2023  Shanghai Materia Medica, Chinese Academy of Sciences.  All rights reserved.